CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING ROOFING WATERSTOPS WATERPROOFING JOINT FILLERS TIMBER FLOORING ALPHABETICAL Fosroc® Proofex Engage Properties Test Method Standard EN13967 Requirement INDEX 536 Page 2 Result Watertightness to liquid EN 1928 Method A No evidence of water penetration @ 6m head Pass Resistance to static loading EN 12730 method B - 15kg Tensile properties (un-reinforced membrane): Tensile strength/elongation at break/elongation at peak load EN 12311-2 - Transverse: >8.0 N/mm² / >200% / >65% Longitudinal: >10.0 N/mm² / >300% / >60% Durability of watertightness against ageing EN 12691 Method A - 1500 mm Resistance to tear (nail shank) EN 12310-1 - 720 N (longitudinal) Reaction to fire EN ISO 11925-2 - Pass Tear resistance - ≥ 600 N Joint strength EN 12317-2 - ≥ 220 N (lap) ≥ 150 N (butt) Water vapour transmission EN 1931 - Water vapour resistance factor u = 580000 Equivalent air layer thickness S = 400 metres Resistance to alkali EN 1847 / EN 1928 Watertight @ 2kPa @ 60kPa @ 2kPa - Pass @ 60kPa - Pass Length Width Thickness Mass Straightness Visible defects EN 1848-2 - 30 metres 1.27 metres 4-5mm (membrane thickness 0.8mm) 1.54 kg/m² <75 mm per 10 metre length Free from visible defects Methane permeability BS903 PT. A30 - 1.33E-17 m²/sec/Pa CO2 permeability Rilem Report 12 - <5.12 E-13 m²/sec/Pa