Page 546

Technical Dayta Sheet Compedium

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING ROOFING WATERSTOPS WATERPROOFING JOINT FILLERS TIMBER FLOORING ALPHABETICAL Vandex® Uni Mortar 1-Z do NOT add more water, simply stir the product to restore workability. Ensure that all surfaces to which Vandex Uni Mortar 1-Z will be applied are pre-watered. The correct amount of prewatering is measured by the substrate taking on a greenish appearance, however there must be no free surface water. A simple check can be performed by placing a hand on the pre-watered substrate and removing the hand. If the hand is wet from contact with the substrate, then the substrate is too wet and must be allowed time for the excess surface water to evaporate. Surfaces that have been pre-watered and dry out before application of the Vandex Uni Mortar 1-Z must be pre-watered again. Apply the mixed Uni Mortar 1-Z from the base of the wall and work towards the top using a trowel or spray equipment. If a second application is required, allow the first layer to reach initial cure before applying a second layer. After 4 - 5 hours apply the second layer ‘green on green’ so that a chemical bond is achieved between the two layers. When applying Vandex Uni Mortar 1-Z by spray ensure that the gun is held directly perpendicular to the surface to ensure that the maximum impact energy is applied to the surface and to prevent any shadowing across surface imperfections. After application of the first coat by spray, brush or trowel the wet surface to remove any entrapped air. If other products are to be applied over Vandex Uni Mortar 1-Z, roughen the surface slightly by brushing or brooming the surface of the Uni Mortar 1-Z while it is still wet. The cure time of Vandex Uni Mortar 1-Z is affected by both temperature and humidity. Humidity has an influence on waiting times between layers and resistance to rain. Ensure that the freshly applied Uni Mortar 1-Z is protected from rain for the first day, and the drying effects of the sun and wind during the first 5 days of cure. In most waterproofing applications, Vandex Uni Mortar 1-Z is applied in one application by trowel or spray. Apply one layer by trowel or spray at an application rate of 12 - 24 kg / m² (Minimum layer thickness must be 6.0 mm). Curing and protection Surfaces treated with Vandex Uni Mortar 1-Z must be kept damp and must be protected from the drying action of direct sunlight for a minimum period of 5 days after application. Important notice A Safety Data Sheet (SDS) and Technical Data Sheet (TDS) are available from the Parchem website or upon request from the nearest Parchem sales office. Read the SDS and TDS carefully prior to use as application or performance data may change from time to time. In emergency, contact any Poisons Information Centre (phone 13 11 26 within Australia) or a doctor for advice. ® Product disclaimer This Technical Data Sheet (TDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time. You should read this TDS carefully and consider the information in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. Parchem does not accept any liability either directly or indirectly for any losses suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it. INDEX 534 Page 3 Parchem Construction Supplies Pty Ltd 7 Lucca Road, Wyong NSW 2259 Phone: 1300 737 787 www.parchem.com.au ABN 80 069 961 968 Distributed in New Zealand by: Concrete Plus Ltd 23 Watts Rd, Sockburn 8042 Ph: 03 343 0090 ® Protect all treated surfaces from wind and frost, by covering with plastic sheeting, damp hessian or equivalent. Cleaning Tools and equipment should be cleaned with water immediately after use. Limitations Vandex Uni Mortar 1-Z is suitable for use in open headed sewerage processing tanks. Consult Parchem for specific advise on the use of Vandex Uni Mortar 1-Z in closed sewerage environments where sulphuric acid concentrations may be high. In negative side applications, do not apply Vandex Uni Mortar 1-Z to substrates that are weeping. Use Vandex Plug to stop all water seepage before applying Uni Mortar 1-Z. Supply Vandex Uni Mortar 1-Z: 25 kg bag Product Code: 751008 Vandex Plug: Product Code: 751006 15 kg resealable plastic pail Coverage Vandex Uni Mortar 1-Z: 12 - 24 kg / m² 1 - 2 m² / 25 kg bag Storage 12 months in original containers stored in cool, dry conditions i.e. not exceeding 30°C. Storage above this temperature may reduce storage life. Equipment Slurry application - Trowel. Spray application - mortar slurry spray gun with an 8 - 16 mm nozzle with air introduced at the nozzle. Air compressor capable of 5 bar pressure and an air capacity of 500 litres/minute with the regulator set to a pressure of 1.0 - 2.0 bar by means of a pressure reducer. Mortar pump capable of 12 to 20 bar max at the worm depending on the length of hose (60 metre max hose length).


Technical Dayta Sheet Compedium
To see the actual publication please follow the link above