Page 310

Technical Dayta Sheet Compedium

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING ROOFING WATERSTOPS WATERPROOFING JOINT FILLERS TIMBER FLOORING ALPHABETICAL Important notice A Safety Data Sheet (SDS) and Technical Data Sheet (TDS) are available from the Parchem website or upon request from the nearest Parchem sales office. Read the SDS and TDS carefully prior to use as application or performance data may change from time to time. In emergency, contact any Poisons Information Centre (phone 13 11 26 within Australia) or a doctor for advice. Product disclaimer This Technical Data Sheet (TDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time. You should read this TDS carefully and consider the information in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. Parchem does not accept any liability either directly or indirectly for any losses suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it. INDEX 298 Page 2 Parchem Construction Supplies Pty Ltd 7 Lucca Road, Wyong NSW 2259 Phone: 1300 737 787 www.parchem.com.au ABN 80 069 961 968 Distributed in New Zealand by: Concrete Plus Ltd 23 Watts Rd, Sockburn 8042 Ph: 03 343 0090 Durafloor® HD-S System Apply first coat at approximately 30 - 40 m²/litre. Increase coverage rate on highly polished floors. Allow to dry for at least 30 minutes and apply subsequent coats at the same application rate allowing each coat to completely dry. Apply a minimum of two coats of Durafloor HD-S. Allow Durafloor HD-S one hour to dry after final coat, prior to foot traffic. Durafloor HD-S System must be free from contact with water for at least 72 hours in ambient temperature to allow cure time. Humidity will delay cure time, therefore humidity should be reduced by using a fan etc. After 72 hours, the surface treated can be damp mopped or scrubbed with an auto scrubber and neutral cleaner. Periodic Maintenance Surface should be regularly cleaned with a neutral cleaner to achieve optimum performance and longevity. Mixing Material should be well agitated. Cleaning Clean all equipment with soap and warm water. Coverage Apply Durafloor HD at approximately 7 - 10 m²/litre depending on surface porosity. Apply Durafloor HD-S at approximately 30 - 40 m²/litre depending on surface porosity and sheen. Limitations „ Durafloor HD will not penetrate curing compounds or other coatings on the concrete being treated. These must be removed by mechanical means such as diamond grinding. „ Coverage and consumption rates will vary depending on porosity and roughness of concrete being treated. „ Stain resistance and sheen level will vary depending on porosity and roughness of concrete being treated. „ Liquid hardeners / densifiers work by reacting with Calcium Hydroxide available in the concrete. If the concrete had been rain affected or overworked in the laying process there may not be sufficient Calcium Hydroxide present for the reaction to occur. These products will not fix bad concrete. „ The final grind may affect the overall characteristics of the floor. It is recommended to carry out grinding and slip trials on projects where slip may be of concern. „ Material cannot be applied in below freezing temperatures. „ Adverse weather conditions or humidity may affect cure time and application rates. Parchem recommends discussing application directly with our Technical Department. Supply 505002 - Durafloor HD: 5 L 505001 - Durafloor HD: 20 L 505505 - Durafloor HD: 200 L 505004 - Durafloor HD-S: 5 L 505003 - Durafloor HD-S: 20 L Specification Clause Refer to Parchem website for detailed specification clauses. Storage Do not allow to freeze. Keep container closed when not in use. Do not transfer material into other containers for storage or disposal. Shelf life All products have a shelf life of 12 months if kept in a dry store in the original, unopened packs.


Technical Dayta Sheet Compedium
To see the actual publication please follow the link above