Page 241

Technical Dayta Sheet Compedium

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING JOINT FILLERS WATERPROOFING WATERSTOPS ROOFING TIMBER FLOORING ALPHABETICAL INDEX Important notice A Safety Data Sheet (SDS) and Technical Data Sheet (TDS) are available from the Parchem website or upon request from the nearest Parchem sales office. Read the SDS and TDS carefully prior to use as application or performance data may change from time to time. In emergency, contact any Poisons Information Centre (phone 13 11 26 within Australia) or a doctor for advice. Product disclaimer This Technical Data Sheet (TDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time. You should read this TDS carefully and consider the information in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. Parchem does not accept any liability either directly or indirectly for any losses suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it. Page 2 229 *Manufactured and sold under license from Fosroc International Limited. Fosroc and the Fosroc logo are trade marks of Fosroc International Limited, used under license. *Denotes a trade mark of Fosroc International Limited. Parchem Construction Supplies Pty Ltd 7 Lucca Road, Wyong NSW 2259 Phone: 1300 737 787 www.parchem.com.au ABN 80 069 961 968 Distributed in New Zealand by: Concrete Plus Ltd 23 Watts Rd, Sockburn 8042 Ph: 03 343 0090 Fosroc® Nitoflor FC120 HB sufficient preparation. Coating Thoroughly stir the product before use. Apply not less than two (2) coats of Nitoflor FC120 HB by rollers at a coverage rate of 3 - 5 m² per litre per coat. The coverage obtained will vary depending on the nature of the surface to be coated. Three (3) coats may be required on porous or coarse surfaces. Or alternatively apply a primer coat of Concure CR, prior to the application of Nitoflor FC120 HB. Where possible apply with minimum strokes of the roller as stringing may occur with successive strokes as solvent evaporates from the applied coating. Wait a minimum of 24 hours between coats. Ensure the first coat is completely dry before applying the next coat. Cleaning Nitoflor FC120 HB should be removed from tools and equipment with Solvent 10 immediately after use. Limitations Nitoflor FC120 HB should not be applied on to surfaces known to suffer from rising damp or having a relative humidity reading greater than 80% . The life expectancy of Nitoflor FC120 HB is reduced in areas of very heavy traffic such as around work benches, drinks machines etc. It is advisable to either:- a) specify additional coats in such areas or, b) specify a higher build epoxy system. Nitoflor FC120 HB should not be applied at temperatures below 10°C or where ambient relative humidity exceeds 85%. Nitoflor FC120 HB should not be applied when the ambient temperature will exceed 30°C during application or within 24 hours after application, otherwise bubbling is liable to occur. Nitoflor FC120 HB contains a significant level of flammable solvent which is expelled to the surrounding air during the drying process. Suitable ventilation and the relevant OH&S precautions must be employed during and after application. Nitoflor FC120 HB is resistant to occassional fuel / petrol spillage providing spillages are cleaned up and not left to ‘pond’ in areas. Supply Nitoflor FC120 HB: 20 litre drum 411050 Nitoflor FC120 hb black 20L 411070 Nitoflor FC120 hb silver grey 20L Coverage Nitoflor FC120 HB Typical coverage 5.0 (m²/l per coat): Theoretical wet film thickness (microns per coat): 200 Theoretical dry film thickness (microns per coat): 80 The coverage figures given are theoretical - due to wastage factors and the variety and nature of possible substrates, practical coverage figures may be reduced. Specification Clause The floor coating shall be Nitoflor FC120 HB, a cholrinated rubber based coating suitable for application by brush or lambswool roller. The coating shall be applied in two coats at a coverage rate not greater than 5 m²/litre per coat. Storage Shelf life Nitoflor FC120 HB have a shelf life of 24 months if kept in a dry store in the original, unopened drums. Storage conditions Product contains highly flammable liquids therefore must be stored in flameproof areas in accordance with local regulations. Store well away from naked flames and sparks and all sources of heat. Store at ambient temperatures below 30°C. Keep container sealed when not in use.


Technical Dayta Sheet Compedium
To see the actual publication please follow the link above