Page 173

Technical Dayta Sheet Compedium

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING JOINT FILLERS WATERPROOFING WATERSTOPS ROOFING TIMBER FLOORING ALPHABETICAL INDEX Important notice A Safety Data Sheet (SDS) and Technical Data Sheet (TDS) are available from the Parchem website or upon request from the nearest Parchem sales office. Read the SDS and TDS carefully prior to use as application or performance data may change from time to time. In emergency, contact any Poisons Information Centre (phone 13 11 26 within Australia) or a doctor for advice. Product disclaimer This Technical Data Sheet (TDS) summarises our best knowledge of the product, including how to use and apply the product based on the information available at the time. You should read this TDS carefully and consider the information in the context of how the product will be used, including in conjunction with any other product and the type of surfaces to, and the manner in which, the product will be applied. Our responsibility for products sold is subject to our standard terms and conditions of sale. Parchem does not accept any liability either directly or indirectly for any losses suffered in connection with the use or application of the product whether or not in accordance with any advice, specification, recommendation or information given by it. Page 3 161 *Manufactured and sold under license from Fosroc International Limited. Fosroc and the Fosroc logo are trade marks of Fosroc International Limited, used under license. *Denotes a trade mark of Fosroc International Limited. Parchem Construction Supplies Pty Ltd 7 Lucca Road, Wyong NSW 2259 Phone: 1300 737 787 www.parchem.com.au ABN 80 069 961 968 Distributed in New Zealand by: Concrete Plus Ltd 23 Watts Rd, Sockburn 8042 Ph: 03 343 0090 accomplished by using portable spray equipment of the knapsack-type. A uniform surface appearance (sheen) should be achieved. If any matt porous patches remain, a further application of primer should be made. The primer should be allowed to dry for a minimum of two hours (at 20°C) before continuing. Under no circumstances should the primer be overcoated with Dekguard E2000 until the surface is properly dry. Dekguard E2000 may be applied by the use of suitable brushes, rollers or spray equipment. All primed substrates should be treated with one or two coats of Dekguard E2000 as specified. It is important that no gaps or ‘raw edges’ appear in the finished coating. Special care should be taken to provide an unbroken coating at external corners and similar exposed protrusions. Spray application When being applied to well prepared surfaces (no blow holes) it is possible to spray apply Dekguard E2000 in a single coat to achieve the 200 micron dry film thickness (400 micron wet film thickness). This can be a substantial time saving on a project. Suitable equipment includes Graco 795 or Graco 1095 airless running at 3000 psi and utilising 19 thou or 21 thou spray tips. For further information contact: Phillro Industries (NSW, Vic & Qld) Ph: 1300 503 610 Pumpline (WA) Ph: 08 9271 2265 Blastmaster (SA) Ph: 1800 882 229 Cleaning Renderoc FC and Dekguard E2000 should be removed from tools and equipment with clean water immediately after use. Nitoprime DG should be removed from tools and equipment using Solvent 10. Limitations The Dekguard E2000 system is formulated for application to clean, sound concrete or masonry. Where application over existing sound coatings or paints is required, trials should be conducted to ensure compatibility and retention of the bond between the underlying coating and the substrate. Compatibility and soundness should be assessed on a trial area. For further advice, consult your local Parchem sales office. Application of Nitoprime DG should not commence if the temperature of the substrate is below 5°C. Application of Dekguard E2000 should not commence if the temperature of the substrate is below 5°C. Dekguard E2000 should not be applied where there is a likelihood of exposure to frost within 48 hours of the application. The product should not be applied in windy conditions where early-age dust adhesion may occur, or where rain is likely within 2 hours at 20°C or 20 hours at 5°C (up to 80% RH). It should not be applied when the prevailing relative humidity exceeds 90%. The use of Dekguard E2000 should not be considered for areas subjected to exposure to ponded water. Dekguard S should be considered in this occasion. Estimating Supply Renderoc FC: 15 kg bags Nitoprime DG: 20 litre drums Dekguard E2000: 15 litre drums (PC: 560625) Solvent 10: 4 & 20 litre drums Coverage Renderoc FC: 9 litres (3.0 m² at 3 mm thickness) Nitoprime DG: 2.5 m² per litre (total) Dekguard E2000: 2.5 m² per litre (total) The coverage figures given are theoretical - due to wastage factors and the variety and nature of possible substrates, practical coverage figures will be reduced. Storage Shelf life All products have a shelf life of 12 months if kept in a dry store in the original, unopened packs. Storage conditions Store in cool, dry conditions, away from sources of heat and naked flames, in the original, unopened packs. If stored at high temperatures and/or high humidity conditions the shelf life may be reduced. Dekguard E2000 should be protected from frost. Fosroc® Dekguard E2000


Technical Dayta Sheet Compedium
To see the actual publication please follow the link above