Page 254

32857 Parchem Technical Data Compendium 2015_Crop4emag.pdf

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING ROOFING WATERSTOPS WATERPROOFING JOINT FILLERS TIMBER FLOORING ALPHABETICAL 'XUDÀRRU® HS back water pressure; otherwise failure of the bond is likely to occur. Intending users should always consult Parchem if there is any doubt as to whether a proposed application may involve conditions other than “ordinary”. Such extraordinary conditions include: ‡ Porous or poor quality concrete causing excessive use INDEX 242 and absorbency of the product. ‡ Unusually cold condition during curing (<10°C) ‡ Above ambient temperatures of service (40°C) eg; floors subject to hot water. ‡ Severe, or unusual, chemical attack. ‡ Severe, or unusual, conditions of service beyond the limiting physical and chemical properties of epoxies. Care should be taken in selecting colours as some will darken or develop a brown tinge when exposed to sunlight or certain chemicals. This effect is noticeable on white, light coloured and grey systems; on brown, yellow and red colours it is less noticeable. Durafloor HS is not recommended for exterior use where it is subjected to sunlight or in applications involving prolonged water immersion. Contact Parchem for detailed information. Cleaning All tools and equipment should be cleaned immediately after use with Solvent 10. Hardened material can only be removed mechanically. Limitations „ Durafloor HS should not be applied to surfaces known to suffer from rising damp or having a relative humidity reading greater than 80%. Refer to Parchem for further advice. „ Durafloor HS should not be applied at temperatures below 10°C. „ Durafloor HS is also not recommended for use where it is subject to high concentrations of hot chicken fat. Refer to Parchem for further information on applications subject to these conditions. „ Durafloor HS is not recommended as an application over tiles. Estimating Supply Total pack size: 8 litres 414600 - Durafloor HS Base 414649 - Durafloor HS Hardener 412040 - Durafloor Medium Grit: 20 kg bags Coverage Average: 5 - 7 m²/litre on concrete per coat The coverage figures given are theoretical - due to wastage factors and the variety and nature of possible substrates, practical coverage figures will be reduced. Storage Shelf Life Durafloor HS has a shelf life of 24 months if kept in a dry place below 35°C in the original, unopened packs. Storage conditions Store in dry conditions between 10°C and 30°C, away from sources of heat and naked flames in the original, unopened packs. If stored at high temperatures the shelf life may be reduced. Durafloor HS should be protected from frost.


32857 Parchem Technical Data Compendium 2015_Crop4emag.pdf
To see the actual publication please follow the link above