Page 176

32857 Parchem Technical Data Compendium 2015_Crop4emag.pdf

CONTENTS CONCRETE REPAIR CORROSION CONTROL GROUTS & ANCHORS PROTECTIVE COATINGS INDUSTRIAL FLOORING SURFACE TREATMENTS JOINT SEALANTS CONCRETE JOINTING ROOFING WATERSTOPS WATERPROOFING JOINT FILLERS TIMBER FLOORING ALPHABETICAL The primer should be allowed to dry for a minimum of two hours (at 20°C) before application of Dekguard O. Under no circumstances should the primer be overcoated until the surface is properly dry. Dekguard O may be applied by the use of suitable brushes, rollers or spray. For further information about application techniques please consult your local Parchem sales office. All primed substrates should be treated with two coats of Dekguard O. The material should be stirred thoroughly before use. The first coat should be applied to all areas by the use of suitable brushes, rollers or spray to achieve a uniform coating with a wet film thickness not less than 200 microns. This coat should be allowed to dry before continuing. The second coat of Dekguard O should be applied exactly as the first, again achieving a wet film thickness not less than 200 microns. Cleaning Renderoc FC should be removed from tools and equipment with clean water immediately after use. Dekguard Primer, Nitoprime DG and Dekguard O should be removed from tools and equipment using Solvent 10. Limitations The Dekguard O system is formulated for application to clean, sound concrete or masonry. Where application over existing sound coatings or paints is required, trials should be conducted to ensure compatibility and retention of the bond between the underlying coating and the substrate. When applied over existing coatings or paints, the performance characteristics of Dekguard O may be impaired and its fire rating invalidated. Compatibility and soundness should be assessed on a trial area. For further advice consult your local Parchem sales office. Application should not commence if the temperature of the substrate is below 2°C. INDEX 164 Estimating Supply Renderoc FC: 15 kg bag Dekguard Primer: 20 litre drum Nitoprime DG: 20 litre drum Dekguard O: 20 litre drum (PC: 560700) Solvent 10: 4 & 20 litre drum Coverage Renderoc FC: 9.0 L (3.0 m² at 3 mm thickness) Dekguard Primer: 2.5 m²/litre (total) Nitoprime DG: 2.5 m²/litre (total) Dekguard O: 2.5 m²/litre (total) The coverage figures given are theoretical - due to wastage factors, the variety and nature of possible substrates, practical coverage figures will be reduced. Storage Shelf life All products have a shelf life of 12 months if kept in a dry store in the original, unopened packs. Storage conditions Store in cool, dry conditions, away from sources of heat and naked flames, in the original, unopened packs. If stored at high temperatures and/or high humidity conditions the shelf life may be reduced. Fosroc® Dekguard O


32857 Parchem Technical Data Compendium 2015_Crop4emag.pdf
To see the actual publication please follow the link above